Network USB plug contains purchased number of licenses, which may be used simultaneously and concurrently by multiple RAM Commander users.

 

Network USB plug should be physically connected to a computer which is always connected to the network and available to all other RAM Commander user computers. "License Manager" software (Windows Service) should be installed and running on this computer.

 

Before the installation, select a computer to act as the “plug server”. The network plug must always be attached to this computer so that users can access RAM Commander. The plug server does not need to be the application server - any other server or workstation will do. The only requirement is that this PC must be switched on whenever someone is using RAM Commander. Plug server and RAM Commander network server could reside on the same PC.

 

Note Only an authorized network administrator should perform this installation procedure.

 

The installation procedure is provided below:

 

1.Choose Plug Server PC.
2.Connect Network plug to the USB port of the Plug Server computer.
3.Run HASP License Manager Setup utility - Run the program lmsetup.exe from the RAM Commander installation CD "\HASP\Servers" folder with the latest version number in folder's name. You may also download the License Manager Setup from our website: https://www.aldsoftware.com/download/download/HASP_LM_setup.zip
4.Choose option to install it as Windows Service - see the picture below:

NetHasp1

5.Proceed with the installation, selecting default options.
6.Choose to start the HASP License Manager immedeately:

NetHasp2

7.After the successful installation, License manager service will be installed and started automatically. RAM Commander users may run their software using network plug.
8.Install Plug Monitor (Optional) - If there is a need to monitor real-time plug status (how many active users connected, who exactly is connected etc.) the Plug Monitor software may be installed – run the setup from RAM Commander installation CD: HASP\MONITOR\AKSMON32.EXE.

 

See the Troubleshooting paragraph for information about different NetHASP plug problems solution.

See Updating plug configuration Reporting plug configuration and paragraphs for information about updating, checking and reporting your plug configuration (allowed modules, number of licenses etc.)

 

Plug update on a virtual server

If your plug server is a virtual machine and you can't perform plug update operations physically on this server PC as required by instructions, you may use another PC and the following procedure:

1. Install RAM Commander (Standalone configuration) on the selected PC (or use any PC with RAM Commander already installed).

2. Install HASP driver: https://www.aldsoftware.com/download/download/HASPUserSetup.exe

3. Take the red USB plug from the server and insert into the USB port of the selected PC.

4. Proceed to the required procedure - Updating plug configuration or Reporting plug configuration.

5. Return the plug back to the server.