In order to generate an adequate MMEL you need to perform Reliability/FMECA and Safety analyses prior to initiating the MMEL Module.

Performance of MMEL quantitative analysis utilizes the following information which is the results of Reliability/FMECA and Safety analyses:

1.Product tree Items data:
a)Item Name (Ref.Des.)
b)Item ATA Number
c)Item operating Failure Rate
2.FHA – Functional Hazard Analysis (Safety module)
3.FMECA – Failure Mode End Effect Criticality Analysis
4.FTA – Fault Tree Analysis
5.Failure modes defined in the FMECA must be used as Basic Events in FTA.
6.Each Basic Event must be connected to a corresponding Failure Mode through Product Tree ID and Failure Mode Number.
7.Each Fault Tree in FTA must be connected to a corresponding Failure Condition in FHA. This connection is established done at the Safety Assessment Definition screen.

 

The picture below illustrates linkage between Product tree, FMECA, FTA and Safety (FHA) modules which is used by MMEL module: