Burn-in is the operation of a component under severe temperature and stress conditions to stabilize its performance. Burn-in reports may only be generated when using the Telecordia (formerly Bellcore), Bellcore Issue 5 or 6 reliability prediction methods. Before selecting the burn-in option from the Reports menu, define the burn-in time and burn‑in temperature for the desired items, as follows:

To define global burn-in time and burn-in temperature

1In the Product tree view, navigate to the top of the product tree.
2From the Tree menu, choose Edit

    - OR -

   right-click the mouse and select Edit.

3In the Tree level item dialog box, enter values for:
Burn-in Temperature in °C; and
Burn-in Time in hours
4Choose OK.

To define specific burn-in time and burn-in temperature

To define a burn-in time and burn-in temperature for a specific item (component or assembly):

1In the Product tree view, navigate to the required item.
2From the Tree menu, choose Edit

     - OR -

   right-click the mouse and select Edit.

3In the Item Data dialog box (Miscellaneous tab), enter values for:
Burn-in Temperature in °C; and
Burn-in Time in hours.
4Choose OK.

To view a Burn-In Report

From the Reports menu, choose Burn-in; the Burn-in report window opens with a first year multiplier for each item. This multiplier is the ratio of the first year failure rate to the steady-state failure rate.