RAM Commander User Manual

Additional operations in FMECA grid

Additional operations in FMECA grid

Previous topic Next topic  

Additional operations in FMECA grid

Previous topic Next topic  

Spelling Checker

You may use spelling checker in FMECA grid - see Spelling checker paragraph in RAM Commander Fundamentals chapter.

 

Copy/Delete Items

You may copy and delete items in the product tree (see the Product Tree Building chapter for more information) . These operations affect FMECA data too:

Copy inside project: When copying inside the project, the item copied will include all FMECA and TAM information. The item is copied with information for all existing phases.
Copy between projects: When copying between projects, the item copied will include all FMECA and TAM information. Any necessary/related data from the FMECA library will also be copied. Items are copied with information from the current phase from the source project to the current phase into the destination project.
Item Delete: When an item is deleted, everything related to the item’s FMECA and TAM information is deleted including all unshared chains up to the EE.

 

Copy FMECA processor data between items

You may copy FMECA data from one item to another in the same project or in different projects. To copy FMECA data,

1.Open two product tree windows:

   a. To copy between items of the same project, choose "New window" from the "Window" menu to open another product tree view window of the same project

   b. To copy between items of different projects, go to the projects list and open the product tree view window of another project.

2.Select items in both windows
3.Choose FMECA mode in both windows
4.Select window with the source information
5.From the Tree menu, choose "Copy processor data".

 

Copy FMECA data between Phases

If you are performing FMECA analysis for several phases and wish to copy all FMECA data from the existing phase to a new empty phase, use <Copy all FMECA data> option of the Phases library.

If you are performing FMECA analysis for several phases and wish to copy FMECA data from the existing phase to a new empty phase for specific item only, perform the following actions:
1.Open project window, choose phase you wish to use as FMECA data source
2.select the required item
3.choose “Copy processor data” from the tree menu
4.choose target phase where you wish to copy data to
5.press ok

 

Popup menus

The FMECA grid is manipulated by invoking pop-up menus with a right mouse click. Each field/column in the FMECA grid has a different pop-up menu displaying the available options.

The next paragraphs provide explanation to these options.