FMEA displays analytical results in a wide variety of tables or graphs. You can export these reports to other programs such as MS-Word or Excel for customized analysis.

Before generating reports, you should use FMEA’s built-in facility to report and automatically correct errors.

1From the Report menu, choose FMEA Analysis.

The FMEA Report generation dialog box opens showing the different reports that can be generated and some radio buttons for sorting and filtering.

 

FMEA_Reports

Sorting by: Sort the report by RPN, by Resulting RPN, or unsorted

Elements: Contents of the report will display either all the Process/Design elements or selected diagram elements only (see Diagram Basics – Multiselection on page 460).

Type: Contents of the report will display either all the Process/Design elements or elements of selected type only.

Only Critical: Contents of the report will display either all the failure causes or only causes marked as Critical Causes.

 

2Choose OK to finish.