RAM Commander User Manual

Equivalent Lambda/MTBF

Equivalent Lambda/MTBF

Previous topic Next topic  

Equivalent Lambda/MTBF

Previous topic Next topic  

Equivalent (Effective) Lambda or Effective MTBF is calculated according to formulas and assumptions described below.

 

Calculation is allowed only with following limitations:

Repairable Configuration (all elements with repair)
Failure Rate distribution - only "Exponential"
Repair Rate distribution – only "Exponential"
K-out-of-N elements:
Load = 100 (active redundancy)
No Switch
No Split

 

Effective λ (FR) equations approximations:

Configuration

λ

µ

RBD_Formula_Serial2

λ = λa + λb

µ = (λaabb)/(λab)

RBD_Sample_Parallel2

RBD_Formula50

(1)

µ = (λaabb)/(λab)

RBD_Formula_KN2

RBD_Formula51

(2)

µ

References (1) and (2) refer to RIAC System Reliability Toolkit, page 394.

 